Medical Image Analysis
Volume 12, Issue 5 , Pages 586-602, October 2008

Model-based blood flow quantification from rotational angiography

  • Irina Waechter

      Affiliations

    • Centre for Medical Image Computing, University College London, United Kingdom
    • Corresponding Author InformationCorresponding author. Tel.: +44 20 7679 0255.
  • ,
  • Joerg Bredno

      Affiliations

    • Philips Research Europe, Aachen, Germany
  • ,
  • Roel Hermans

      Affiliations

    • Philips X-ray Predevelopment, Best, The Netherlands
  • ,
  • Juergen Weese

      Affiliations

    • Philips Research Europe, Aachen, Germany
  • ,
  • Dean C. Barratt

      Affiliations

    • Centre for Medical Image Computing, University College London, United Kingdom
  • ,
  • David J. Hawkes

      Affiliations

    • Centre for Medical Image Computing, University College London, United Kingdom

Received 1 February 2008; received in revised form 14 May 2008; accepted 10 June 2008. published online 19 June 2008.

Abstract 

For assessment of cerebrovascular diseases, it is beneficial to obtain three-dimensional (3D) information on vessel morphology and haemodynamics. Rotational angiography is routinely used to determine the 3D geometry. In this paper, we propose a method to exploit the same acquisition to determine the blood flow waveform and the mean volumetric flow rate in the large cerebral arteries.

The method uses a model of contrast agent dispersion to determine the flow parameters from the spatial and temporal progression of the contrast agent concentration, represented by a flow map. Furthermore, it overcomes artefacts due to the rotation (overlapping vessels and foreshortened vessels at some projection angles) of the C-arm using a reliability map.

The method was validated on images from different phantom experiments. We analysed different properties of the flow quantification method, including the influence of noise and the influence of the length of the analysed blood vessel.

In most cases, the relative error was between 5% and 10% for the volumetric mean flow rate and between 10% and 15% for the blood flow waveform. The manual interaction took at most one minute and the computational time for the flow quantification was between 4 and 20min on a PC. From this, we conclude that the method has the potential to give quantitative estimates of blood flow parameters during cerebrovascular interventions.

Keywords: Flow quantification, Flow model, Rotational angiography

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S1361-8415(08)00064-9

doi:10.1016/j.media.2008.06.003

Medical Image Analysis
Volume 12, Issue 5 , Pages 586-602, October 2008