Medical Image Analysis
Volume 14, Issue 2 , Pages 149-159, April 2010

Automated detection of intracranial aneurysms based on parent vessel 3D analysis

  • Alexandra Lauric

      Affiliations

    • Tufts University, Department of Computer Science, 161 College Ave, Medford, MA 02155, United States
    • Corresponding Author InformationCorresponding author. Tel.: +1 7816486819.
  • ,
  • Eric Miller

      Affiliations

    • Tufts University, Department of Computer Science, 161 College Ave, Medford, MA 02155, United States
    • Tufts University, Department of Electrical and Computer Engineering, 161 College Ave, Medford, MA 02155, United States
  • ,
  • Sarah Frisken

      Affiliations

    • Tufts University, Department of Computer Science, 161 College Ave, Medford, MA 02155, United States
  • ,
  • Adel M. Malek

      Affiliations

    • Tufts University School of Medicine, 145 Harrison Ave, Boston, MA 02111, United States
    • Tufts Medical Center, Department of Neurosurgery, 800 Washington St., Boston, MA 02111, United States

Received 8 December 2008; received in revised form 20 October 2009; accepted 29 October 2009. published online 12 November 2009.

Abstract 

The detection of brain aneurysms plays a key role in reducing the incidence of intracranial subarachnoid hemorrhage (SAH) which carries a high rate of morbidity and mortality. The majority of non-traumatic SAH cases is caused by ruptured intracranial aneurysms and accurate detection can decrease a significant proportion of misdiagnosed cases. A scheme for automated detection of intracranial aneurysms is proposed in this study. Applied to the segmented cerebral vasculature, the method detects aneurysms as suspect regions on the vascular tree, and is designed to assist diagnosticians with their interpretations and thus reduce missed detections. In the current approach, the vessels are segmented and their medial axis is computed. Small regions along the vessels are inspected and the writhe number is introduced as a new surface descriptor to quantify how closely any given region approximates a tubular structure. Aneurysms are detected as non-tubular regions of the vascular tree. The geometric assumptions underlying the approach are investigated analytically and validated experimentally. The method is tested on 3D-rotational angiography (3D-RA) and computed tomography angiography (CTA). In our experiments, 100% sensitivity was achieved with average false positives rates of 0.66 per study on 3D-RA data and 5.36 false positive rates per study on CTA data.

Keywords: Intracranial aneurysms, Aneurysm detection, Computed-aided diagnostic, Surface descriptor, Writhe number

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S1361-8415(09)00121-2

doi:10.1016/j.media.2009.10.005

Medical Image Analysis
Volume 14, Issue 2 , Pages 149-159, April 2010