Medical Image Analysis
Volume 14, Issue 2 , Pages 227-241, April 2010

Wavelet optimization for content-based image retrieval in medical databases

  • G. Quellec

      Affiliations

    • Institut Telecom, Telecom Bretagne, UEB, Dpt ITI, Brest F-29200, France
    • Inserm, U650, IFR 148 ScInBioS, Brest F-29200, France
  • ,
  • M. Lamard

      Affiliations

    • Univ Bretagne Occidentale, Brest F-29200, France
    • Inserm, U650, IFR 148 ScInBioS, Brest F-29200, France
    • Corresponding Author InformationCorresponding author. Address: Univ Bretagne Occidentale, Brest F-29200, France. Tel.: +33 298018110; fax: +33 298018124.
  • ,
  • G. Cazuguel

      Affiliations

    • Institut Telecom, Telecom Bretagne, UEB, Dpt ITI, Brest F-29200, France
    • Inserm, U650, IFR 148 ScInBioS, Brest F-29200, France
  • ,
  • B. Cochener

      Affiliations

    • Univ Bretagne Occidentale, Brest F-29200, France
    • Inserm, U650, IFR 148 ScInBioS, Brest F-29200, France
    • CHU Brest, Service d’Ophtalmologie, Brest F-29200, France
  • ,
  • C. Roux

      Affiliations

    • Institut Telecom, Telecom Bretagne, UEB, Dpt ITI, Brest F-29200, France
    • Inserm, U650, IFR 148 ScInBioS, Brest F-29200, France

Received 14 April 2008; received in revised form 7 November 2009; accepted 11 November 2009. published online 18 November 2009.

Abstract 

We propose in this article a content-based image retrieval (CBIR) method for diagnosis aid in medical fields. In the proposed system, images are indexed in a generic fashion, without extracting domain-specific features: a signature is built for each image from its wavelet transform. These image signatures characterize the distribution of wavelet coefficients in each subband of the decomposition. A distance measure is then defined to compare two image signatures and thus retrieve the most similar images in a database when a query image is submitted by a physician. To retrieve relevant images from a medical database, the signatures and the distance measure must be related to the medical interpretation of images. As a consequence, we introduce several degrees of freedom in the system so that it can be tuned to any pathology and image modality. In particular, we propose to adapt the wavelet basis, within the lifting scheme framework, and to use a custom decomposition scheme. Weights are also introduced between subbands. All these parameters are tuned by an optimization procedure, using the medical grading of each image in the database to define a performance measure. The system is assessed on two medical image databases: one for diabetic retinopathy follow up and one for screening mammography, as well as a general purpose database. Results are promising: a mean precision of 56.50%, 70.91% and 96.10% is achieved for these three databases, when five images are returned by the system.

Keywords: Content-based image retrieval, Custom wavelet, Lifting scheme, Diabetic retinopathy, Mammography

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S1361-8415(09)00141-8

doi:10.1016/j.media.2009.11.004

Medical Image Analysis
Volume 14, Issue 2 , Pages 227-241, April 2010