Medical Image Analysis
Volume 14, Issue 3 , Pages 303-317, June 2010

A fast and robust patient specific Finite Element mesh registration technique: Application to 60 clinical cases

  • Marek Bucki

      Affiliations

    • TIMC-IMAG Laboratory, UMR CNRS 5525, University Joseph Fourier, 38706 La Tronche, France
    • Corresponding Author InformationCorresponding author.
  • ,
  • Claudio Lobos

      Affiliations

    • Departamento de Informática, Universidad Técnica Federico Santa María, Av. Vicuña Mackenna 3939, Zip 8940897, San Joaquín, Santiago, Chile
  • ,
  • Yohan Payan

      Affiliations

    • TIMC-IMAG Laboratory, UMR CNRS 5525, University Joseph Fourier, 38706 La Tronche, France
    • PIMS-Europe, UMI CNRS 3069, 200-1933 West Mall, University of British Columbia, Vancouver, BC V6T 1Z2, Canada

Received 4 June 2009; received in revised form 3 February 2010; accepted 4 February 2010. published online 16 February 2010.

Abstract 

Finite Element mesh generation remains an important issue for patient specific biomechanical modeling. While some techniques make automatic mesh generation possible, in most cases, manual mesh generation is preferred for better control over the sub-domain representation, element type, layout and refinement that it provides. Yet, this option is time consuming and not suited for intraoperative situations where model generation and computation time is critical. To overcome this problem we propose a fast and automatic mesh generation technique based on the elastic registration of a generic mesh to the specific target organ in conjunction with element regularity and quality correction. This Mesh-Match-and-Repair (MMRep) approach combines control over the mesh structure along with fast and robust meshing capabilities, even in situations where only partial organ geometry is available. The technique was successfully tested on a database of 5 pre-operatively acquired complete femora CT scans, 5 femoral heads partially digitized at intraoperative stage, and 50 CT volumes of patients’ heads. In the latter case, both skin and bone surfaces were taken into account by the mesh registration process in order to model the face muscles and fat layers. The MMRep algorithm succeeded in all 60 cases, yielding for each patient a hex-dominant, Atlas based, Finite Element mesh with submillimetric surface representation accuracy, directly exploitable within a commercial FE software.

Keywords: Mesh generation, Finite Element Method, Elastic registration, Mesh repair

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S1361-8415(10)00018-6

doi:10.1016/j.media.2010.02.003

Medical Image Analysis
Volume 14, Issue 3 , Pages 303-317, June 2010