Medical Image Analysis
Volume 15, Issue 1 , Pages 45-52 , February 2011

Characterization of frequency-dependent material properties of human liver and its pathologies using an impact hammer

  • M. Umut Ozcan

      Affiliations

    • College of Engineering, Koc University, Istanbul, Turkey
  • ,
  • Sina Ocal

      Affiliations

    • College of Engineering, Koc University, Istanbul, Turkey
  • ,
  • Cagatay Basdogan

      Affiliations

    • College of Engineering, Koc University, Istanbul, Turkey
    • Corresponding Author InformationCorresponding author. Address: College of Engineering, Koc University, Rumelifeneri yolu, Istanbul 34450, Turkey. Tel.: +90 212 338 1721; fax: +90 212 338 1548.
  • ,
  • Gulen Dogusoy

      Affiliations

    • Department of Pathology, Cerrahpasa Medical School, Istanbul University, Istanbul, Turkey
  • ,
  • Yaman Tokat

      Affiliations

    • Liver Transplant Center, Florence Nightingale Hospital, Istanbul, Turkey

Received 19 January 2010 ,Revised 23 June 2010 ,Accepted 25 June 2010.

References 

  1. Bensamoun SF, Wang L, Robert L, Charleux F, Latrive JP, Ho Ba Tho MC. Measurement of liver stiffness with two imaging techniques: magnetic resonance elastography and ultrasound elastography. Journal of Magnetic Resonance Imaging. 2008;28:1287–1292
  2. Gao Z, Desai J. Estimating zero-strain states of very soft tissue under gravity loading using digital image correlation. Medical Image Analysis. 2010;14(2):126–137
  3. Hu T, Lau A, Desai J. Instrumentation for testing soft tissue undergoing large deformation: ex vivo and in vivo studies. Journal of Medical Devices. 2008;2:041001-1–041001-6
  4. Huwart L, Peeters F, Sinkus R, Annet L, Salameh N, ter Beek LC, et al. Liver fibrosis: non-invasive assessment with MR elastography. NMR in Biomedicine. 2006;19:173–179
  5. Kerdok AE, Ottensmeyer MP, Howe RD. Effects of perfusion on the viscoelastic characteristics of liver. Journal of Biomechanics. 2006;39(12):2221–2231
  6. Kiss MZ, Varghese T, Hall TJ. Viscoelastic characterization of in vitro canine tissue. Physics in Medicine and Biology. 2004;49(18):4207–4218
  7. Lin TR, Farag NH, Pan J. Evaluation of frequency dependent rubber mount stiffness and damping by impact test. Applied Acoustics. 2005;66(7):829–844
  8. Liu Z, Bilston L. On the viscoelastic character of liver tissue: experiments and modeling of the linear behavior. Biorheology. 2000;37(3):191–201
  9. Lucidarme D, Foucher J, Le Bail B, Vergniol J, Castera L, Duburque C, et al. Factors of accuracy of transient elastography (FibroScan) for the diagnosis of liver fibrosis in chronic hepatitis C. Hepatology. 2009;49:1083–1089
  10. Manduca A, Oliphant TE, Dresner MA, Mahowald JL, Kruse SA, Amromin E, et al. Magnetic resonance elastography: non-invasive mapping of tissue elasticity. Medical Image Analysis. 2001;5(4):237–254
  11. Mazza E, Nava A, Hahnloser D, Jochum W, Bajka M. The mechanical response of human liver and its relation to histology: an in vivo study. Medical Image Analysis. 2007;11:663–672
  12. Nashif AD, Jones D, Henderson JP. Vibration Damping. Wiley; 1985;
  13. Nava A, Mazza E, Furrer M, Villiger P, Reinhart WH. In vivo mechanical characterization of human liver. Medical Image Analysis. 2008;12:203–216
  14. Ottensmeyer, M.P., 2001. Minimally invasive instrument for in vivo measurement of solid organ mechanical impedance. Ph.D. Thesis, Department of Mechanical Engineering, MIT.
  15. Rosen, J., Brown, J.D., De, S., Sinanan, M., Hannaford, B., 2008. Biomechanical properties of abdominal organs in vivo and postmortem under compression loads. Journal of Biomechanical Engineering 130(2), 021020-1–021020-16.
  16. Rouviere O, Yin M, Dresner MA, Rossman PJ, Burgart LJ, Fidler JL, et al. MR elastography of the liver: preliminary results. Radiology. 2006;240(2):440–448
  17. Samur E, Sedef M, Basdogan C, Avtan L, Duzgun O. A robotic indenter for minimally invasive measurement and characterization of soft tissue behavior. Medical Image Analysis. 2007;11(4):361–373
  18. Sandrin L, Fourquet B, Hasquenoph JM, Yon S, Fournier C, Mal F, et al. Transient elastography: a new noninvasive method for assessment of hepatic fibrosis. Ultrasound in Medicine and Biology. 2003;29(12):1705–1713
  19. Saraf H, Ramesh KT, Lennon AM, Merkle AC, Roberts JC. Mechanical properties of soft human tissues under dynamic loading. Journal of Biomechanics. 2007;40(9):1960–1967
  20. Valtorta D, Mazza E. Dynamic measurement of soft tissue viscoelastic properties with a torsional resonator device. Medical Image Analysis. 2005;9:481–490
  21. Ziol M, Handra-Luca A, Kettaneh A, Christidis C, Mal F, Kazemi F, et al. Noninvasive assessment of liver fibrosis by measurement of stiffness in patients with chronic hepatitis C. Hepatology. 2005;41(1):48–54

PII: S1361-8415(10)00082-4

doi: 10.1016/j.media.2010.06.010

Medical Image Analysis
Volume 15, Issue 1 , Pages 45-52 , February 2011