Medical Image Analysis
Volume 15, Issue 1 , Pages 85-95 , February 2011

Geometrical analysis of registration errors in point-based rigid-body registration using invariants

  • Reuben R. Shamir

      Affiliations

    • Corresponding Author InformationCorresponding author. Address: School of Engineering and Computer Science, The Hebrew University of Jerusalem, Givat Ram Campus, Jerusalem 91904, Israel. Tel.: +972 508 712 714.
  • ,
  • Leo Joskowicz

Received 17 November 2009 ,Revised 8 July 2010 ,Accepted 15 July 2010.

References 

  1. Ellis R, Toksvig-Larsen S, Marcacci M, Caramella D, Fadda M. Use of a biocompatible fiducial marker in evaluating the accuracy of computed tomography image registration. Invest. Radiol. 1996;31(10):658–667
  2. Fitzpatrick JM. Detecting failure, assessing success. In:  Hajnal JV,  Hill DLG,  Hawkes DJ editor. Medical Image Registration. CRC Press; 2001;p. 117–137
  3. Fitzpatrick, J.M., 2009. Fiducial registration error and target registration error are uncorrelated. In: Miga, M.I., Wong, K.H. (Eds.), SPIE Medical Imaging 2009: Visualization, Image-Guided Procedures, and Modeling.
  4. Fitzpatrick JM, West JB. The distribution of target registration error in rigid-body point-based registration. IEEE Trans. Med. Imaging. 2001;20(9):917–927
  5. Fitzpatrick JM, West JB, Maurer CR. Predicting error in rigid-body point-based registration. IEEE Trans. Med. Imaging. 1998;17(5):694–702
  6. Gholipour A, Kehtarnavaz N, Briggs R, Devous M, Gopinath K. Brain functional localization: a survey of image registration techniques. IEEE Trans. Med. Imaging. 2007;26(4):427–451
  7. Golub GH, Van Loan CF. Matrix Computations. The Johns Hopkins University Press; 1996;
  8. Guler, O., Schwarm, F., Bickel, M., Kral, F., Freyzinger, W., 2009. Validation of least-squares and algebraic registration approaches for intraoperative 3D visualization around the head. In: The 23rd International Congress on Computer Assisted Radiology and Surgery (CARS’09), pp. 264–265.
  9. Hartley RI, Zisserman A. Multiple View Geometry in Computer Vision. Cambridge University Press; 2004;
  10. Hawkes DJ. Registration methodology: introduction. In:  Hajnal JV,  Hill DLG,  Hawkes DJ editor. Medical Image Registration. CRC Press; 2001;p. 11–38
  11. Kremser C, Plangger C, Bosecke R, Pallua A, Aichner F, Felber SR. Image registration of MR and CT images using a frameless fiducial marker system. Magn. Reson. Imaging. 1997;15(5):579–585
  12. Labadie RF, Shah RJ, Harris SS, Cetinkaya E, Haynes DS, Fenlon MR, et al. Submillimetric target-registration error using a novel, non-invasive fiducial system for image-guided otologic surgery. Comput. Aided Surg. 2004;9(4):145–153
  13. Lorusso, A., Eggert, D.W., Fisher, R.B., 1995. A comparison of four algorithms for estimating 3-D rigid transformations. British Machine Vision Conference, A20.
  14. Ma B, Moghari MH, Ellis RE, Abolmaesumi P. On fiducial target registration error in the presence of anisotropic noise. Med. Image Comput. Comput. Assist. Interv. 2007;10(Pt. 2):628–635
  15. Ma B, Moghari MH, Ellis RE, Abolmaesumi P. Estimation of optimal fiducial target registration error in the presence of heteroscedastic noise. IEEE Trans. Med. Imaging. 2010;29(3):708–723
  16. Maurer CR, Fitzpatrick JM, Wang MY, Galloway RL, Maciunas RJ, Allen GS. Registration of head volume images using implantable fiducial markers. IEEE Trans. Med. Imaging. 1997;16(4):447–462
  17. Mermershtain W, Cohen Y, Krutman Y. Accuracy of prostate radiation therapy using a fiducial point-pair registration technique based on the computer-assisted portal imaging quality assurance program PIPSpro. Australas Radiol. 2003;47(2):168–171
  18. Moghari, M.H., Abolmaesumi, P., 2008. Maximum likelihood estimation of the distribution of target registration error. In: Michael, I.M., Kevin, R.C. (Eds.), SPIE Medical Imaging 2008: Visualization, Image-guided Procedures, and Modeling.
  19. Moghari MH, Abolmaesumi P. Distribution of fiducial registration error in rigid-body point-based registration. IEEE Trans. Med. Imaging. 2009;28(11):1791–1801
  20. Moghari MH, Abolmaesumi P. Distribution of target registration error for anisotropic and inhomogeneous fiducial localization error. IEEE Trans. Med. Imaging. 2009;28(6):799–813
  21. Moghari MH, Ma B, Abolmaesumi P. A theoretical comparison of different target registration error estimators. Med. Image Comput. Comput. Assist. Interv. 2008;11(Pt. 2):1032–1040
  22. Olver PJ. Classical Invariant Theory. Cambridge University Press; 1999;
  23. Parker CC, Damyanovich A, Haycocks T, Haider M, Bayley A, Catton CN. Magnetic resonance imaging in the radiation treatment planning of localized prostate cancer using intra-prostatic fiducial markers for computed tomography co-registration. Radiother. Oncol. 2003;66(2):217–224
  24. Ramya, B., Robert, F.L., Fitzpatrick, J.M., 2007. Clinical determination of target registration error of an image-guided otologic surgical system using patients with bone-anchored hearing aids. In: Kevin, R.C., Michael, I.M. (Eds.), SPIE Medical Imaging.
  25. Shamir, R.R., Joskowicz, L., 2009. Worst-case analysis of target localization errors in fiducial-based rigid body registration. In: Pluim, J.P.W., Dawant, B.M. (Eds.), SPIE Medical Imaging 2009: Image Processing.
  26. Shamir, R., Joskowicz, L., Spektor, S., Shoshan, Y., 2009a. Target and trajectory localization accuracy in navigated keyhole neurosurgery. In: The 23rd International Congress on Computer Assisted Radiology and Surgery (CARS’09), Berlin, pp. 249–250.
  27. Shamir RR, Joskowicz L, Spektor S, Shoshan Y. Localization and registration accuracy in image guided neurosurgery: a clinical study. Int. J. Comput. Assist. Radiol. Surg. 2009;4(1):45–52
  28. Shamir, R., Joskowicz, L., Shoshan, Y., 2010. What is the actual fiducial localization error in image-guided neuronavigation?. In: 24th Conference on Computer Assisted Radiology and Surgery (CARS).
  29. Sibson R. Studies in the robustness of multidimensional scaling: perturbational analysis of classical scaling. J. Roy. Stat. Soc. 1979;41(2):217–229
  30. Sielhorst T, Bauer M, Wenisch O, Klinker G, Navab N. Online estimation of the target registration error for n-ocular optical tracking systems. Med. Image Comput. Comput. Assist. Interv. 2007;10(Pt. 2):652–659
  31. West, J.B., Fitzpatrick, J.M., 2000. Point-based, rigid registration: clinical validation of theory. In: Proceedings of the SPIE Medical Imaging San Diego, CA, pp. 353–359.
  32. Wiles AD, Peters TM. Real-time estimation of FLE statistics for 3-D tracking with point-based registration. IEEE Trans. Med. Imaging. 2009;28(9):1384–1398
  33. Wiles AD, Peters TM. Target tracking errors for 5D and 6D spatial measurement systems. IEEE Trans. Med. Imaging. 2010;29(3):879–894
  34. Wiles AD, Likholyot A, Frantz DD, Peters TM. A statistical model for point-based target registration error with anisotropic fiducial localizer error. IEEE Trans. Med. Imaging. 2008;27(3):378–390
  35. Yaniv Z. Rigid registration. In:  Peters T,  Cleary K editor. Image-Guided Interventions: Technology and Applications. New York: Springer; 2008;p. 159–192

PII: S1361-8415(10)00102-7

doi: 10.1016/j.media.2010.07.010

Medical Image Analysis
Volume 15, Issue 1 , Pages 85-95 , February 2011