Real-time image-based rigid registration of three-dimensional ultrasound

  • Robert J. Schneider

      Affiliations

    • Harvard School of Engineering and Applied Sciences, Cambridge, MA, USA
    • Corresponding Author InformationCorresponding author.
  • ,
  • Douglas P. Perrin

      Affiliations

    • Harvard School of Engineering and Applied Sciences, Cambridge, MA, USA
    • Department of Cardiac Surgery, Children’s Hospital, Boston, MA, USA
  • ,
  • Nikolay V. Vasilyev

      Affiliations

    • Department of Cardiac Surgery, Children’s Hospital, Boston, MA, USA
  • ,
  • Gerald R. Marx

      Affiliations

    • Department of Cardiology, Children’s Hospital, Boston, MA, USA
  • ,
  • Pedro J. del Nido

      Affiliations

    • Department of Cardiac Surgery, Children’s Hospital, Boston, MA, USA
  • ,
  • Robert D. Howe

      Affiliations

    • Harvard School of Engineering and Applied Sciences, Cambridge, MA, USA

Received 6 January 2011; received in revised form 14 October 2011; accepted 20 October 2011. published online 16 November 2011.

Graphical abstract

Liver mosaic (right) made from 60+ 3D ultrasound volumes (left). Image-based rigid registration of volumes took an average of 24.4ms per volume.

Highlights

► Presented is a fast image-based rigid registration method for 3D ultrasound. ► Registrations are computed in real-time (i.e. as fast as volumes are acquired). ► Feature detection and descriptor formation account for 3D ultrasound characteristics. ► Efficient use of a global feature set limits the accumulation of registration error. ► Accuracy of the method is comparable to existing rigid registration methods.

Abstract 

Registration of three-dimensional ultrasound (3DUS) volumes is necessary in several applications, such as when stitching volumes to expand the field of view or when stabilizing a temporal sequence of volumes to cancel out motion of the probe or anatomy. Current systems that register 3DUS volumes either use external tracking systems (electromagnetic or optical), which add expense and impose limitations on acquisitions, or are image-based methods that operate offline and are incapable of providing immediate feedback to clinicians. This paper presents a real-time image-based algorithm for rigid registration of 3DUS volumes designed for acquisitions in which small probe displacements occur between frames. Described is a method for feature detection and descriptor formation that takes into account the characteristics of 3DUS imaging. Volumes are registered by determining a correspondence between these features. A global set of features is maintained and integrated into the registration, which limits the accumulation of registration error. The system operates in real-time (i.e. volumes are registered as fast or faster than they are acquired) by using an accelerated framework on a graphics processing unit. The algorithm’s parameter selection and performance is analyzed and validated in studies which use both water tank and clinical images. The resulting registration accuracy is comparable to similar feature-based registration methods, but in contrast to these methods, can register 3DUS volumes in real-time.

Keywords: Ultrasound, Registration, Real-time, Image-based

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S1361-8415(11)00142-3

doi:10.1016/j.media.2011.10.004

Medical Image Analysis
Volume 16, Issue 2 , Pages 402-414, February 2012