Article Title |
Author(s) |
Type (Status) |
Available Online |
|
Understanding the Phase Contrast Optics to Restore Artifact-free Microscopy Images for Segmentation
DOI: 10.1016/j.media.2011.12.006
Graphical abstract Highlights: ► Understand the phase contrast optics and its artifacts. ► Derive the computational imaging model for phase contrast optics. ► Design an effective algorithm to restore ...
|
Zhaozheng Yin,
Takeo Kanade,
Mei Chen
|
Full-length article
(In Press Accepted Manuscript)
|
06 February 2012 |
|
Nonparametric Bayesian inference of the fiber orientation distribution from diffusion-weighted MR images
DOI: 10.1016/j.media.2012.01.004
Graphical abstract: Bayesian density estimation allows us to disentangle three crossing fiber bundles in the centrum semiovale. Highlights: ► The spherical convolution model is reformulated by adoptin...
|
Enrico Kaden,
Frithjof Kruggel
|
Full-length article
(In Press Accepted Manuscript)
|
02 February 2012 |
|
Brain Tissue Segmentation in MR Images based on a Hybrid of MRF and Social Algorithms
DOI: 10.1016/j.media.2012.01.001
Graphical abstract: Effective abnormality detection and diagnosis in Magnetic Resonance Images (MRIs) requires a robust segmentation strategy. Since manual segmentation is a so time-consuming task whi...
|
Sahar Yousefi,
Reza Azmi,
Morteza Zahedi
|
Full-length article
(In Press Accepted Manuscript)
|
02 February 2012 |
|
A Probabilistic Framework for Image Information Fusion with An Application to Mammographic Analysis
DOI: 10.1016/j.media.2012.01.003
Graphical abstract: Highlights: ► We develop a multi-stage probabilistic framework for multi-view image analysis. ► The framework is computationally efficient and quite general to apply to any domain...
|
Marina Velikova,
Peter J.F. Lucas,
Maurice Samulski,
Nico Karssemeijer
|
Full-length article
(In Press Accepted Manuscript)
|
27 January 2012 |
|
A CANDLE for a deeper in vivo insight
DOI: 10.1016/j.media.2012.01.002
Graphical abstract: Optic chiasm between 275μm and 320μm Highlights: ► A new method for the denoising of confocal and multiphoton images is proposed. ► An extensive validation demonstrates the high de...
|
Pierrick Coupé,
Martin Munz,
Jose V. Manjon,
Edward S. Ruthazer,
D. Louis Collins
et al.
|
Full-length article
(In Press Uncorrected Proof)
|
20 January 2012 |
|
Mass preserving image registration for lung CT
DOI: 10.1016/j.media.2011.11.001
Graphical abstract: Improvement of mass preserving image registration for four datasets with increasing differences in lung volume. Highlights: ► Preservation of mass is a plausible model of lung pare...
|
Vladlena Gorbunova,
Jon Sporring,
Pechin Lo,
Martine Loeve,
Harm A. Tiddens,
Mads Nielsen,
Asger Dirksen,
Marleen de Bruijne
et al.
|
Full-length article
(In Press Uncorrected Proof)
|
16 January 2012 |
|
Cardiac MR perfusion image processing techniques: A survey
DOI: 10.1016/j.media.2011.12.005
Graphical abstract: Highlights: ► Survey of semi- and fully automatic image processing methods for cardiac MR perfusion quantification. ► Classification of image processing methods based on their reg...
|
Vikas Gupta,
Hortense A. Kirişli,
Emile A. Hendriks,
Rob J. van der Geest,
Martijn van de Giessen,
Wiro Niessen,
Johan H.C. Reiber,
Boudewijn P.F. Lelieveldt
et al.
|
Review article
(In Press Corrected Proof)
|
11 January 2012 |
|
A fast analysis method for non-invasive imaging of blood flow in individual cerebral arteries using vessel-encoded arterial spin labeling angiography
DOI: 10.1016/j.media.2011.12.004
Graphical abstract: Highlights: ► Non-invasive vessel selective MR angiography. ► Fast Bayesian analysis for artery flow contributions. ► Robust treatment of imperfect artery location specification e...
|
Michael A. Chappell,
Thomas W. Okell,
Stephen J. Payne,
Peter Jezzard,
Mark W. Woolrich
et al.
|
Full-length article
(In Press Accepted Manuscript)
|
29 December 2011 |
|
Nonlinear dimensionality reduction combining MR imaging with non-imaging information
DOI: 10.1016/j.media.2011.12.003
Graphical abstract: The top figure shows a 2D manifold embedding of images acquired from subjects with AD (squares) and healthy controls (circles) using pairwise image similarities with Laplacian Eige...
|
Robin Wolz,
Paul Aljabar,
Joseph V. Hajnal,
Jyrki Lötjönen,
Daniel Rueckert,
The Alzheimer’s Disease Neuroimaging Initiative
et al.
|
Full-length article
(In Press Corrected Proof)
|
26 December 2011 |
|
3D Segmentation of SBFSEM Images of Neuropil by a Graphical Model over Supervoxel Boundaries
DOI: 10.1016/j.media.2011.11.004
Graphical abstract: Highlights: ► We propose a supervoxel merging method for segmenting 3D SBFSEM images of neuropil. ► All merging decisions are coupled in a graphical model. ► Knowledge about corre...
|
Bjoern Andres,
Ullrich Koethe,
Thorben Kroeger,
Moritz Helmstaedter,
Kevin L. Briggman,
Winfried Denk,
Fred A. Hamprecht
et al.
|
Full-length article
(In Press Accepted Manuscript)
|
21 December 2011 |
|
Manifold learning for image-based breathing gating in ultrasound and MRI
DOI: 10.1016/j.media.2011.11.008
Graphical abstract: Highlights: ► Automatic, image-based gating in ultrasound and MRI. ► Application of Laplacian eigenmaps for gating. ► Creation of 4D ultrasound data with wobbler transducer. ► Val...
|
Christian Wachinger,
Mehmet Yigitsoy,
Erik-Jan Rijkhorst,
Nassir Navab
|
Full-length article
(In Press Corrected Proof)
|
09 December 2011 |
|
Multi-modal registration of speckle-tracked freehand 3D ultrasound to CT in the lumbar spine
DOI: 10.1016/j.media.2011.07.006
Graphical abstract: A method for registration of speckle-tracked freehand 3D ultrasound to preoperative CT volumes of the spine is proposed. The method corrects the significant drift error in speckle-...
|
Andrew Lang,
Parvin Mousavi,
Sean Gill,
Gabor Fichtinger,
Purang Abolmaesumi
et al.
|
Full-length article
(In Press Corrected Proof)
|
29 August 2011 |
|
Prostate biopsy tracking with deformation estimation
DOI: 10.1016/j.media.2011.01.008
Graphical abstract: Prostate biopsy core and cancer grade map realized using 3D US image registration based prostate biopsy core tracking with deformation estimation. Highlights: ► Prostate biopsy cor...
|
Michael Baumann,
Pierre Mozer,
Vincent Daanen,
Jocelyne Troccaz
|
Full-length article
(In Press Corrected Proof)
|
18 May 2011 |
|
Context specific descriptors for tracking deforming tissue
DOI: 10.1016/j.media.2011.02.010
Graphical abstract: An adaptive intra-operative tissue deformation tracking framework based on context specific descriptors incorporating both geometric and appearance information that is robust to dr...
|
Peter Mountney,
Guang-Zhong Yang
|
Full-length article
(In Press Corrected Proof)
|
16 May 2011 |
|
Development and comparison of new hybrid motion tracking for bronchoscopic navigation
DOI: 10.1016/j.media.2010.11.001
Graphical abstract: The proposed hybrid motion prediction method comprises main three stages: feature-based motion prediction, Kalman filtering-based scale factor estimation, and intensity-based image...
|
Xióngbiāo Luó,
Marco Feuerstein,
Daisuke Deguchi,
Takayuki Kitasaka,
Hirotsugu Takabatake,
Kensaku Mori
et al.
|
Full-length article
(In Press Corrected Proof)
|
14 December 2010 |
|
MR to ultrasound registration for image-guided prostate interventions
DOI: 10.1016/j.media.2010.11.003
Graphical abstract: Deformable registration between MR and ultrasound images of prostate using a statistical motion model and a novel probabilistic model-to-image registration algorithm. Research high...
|
Yipeng Hu,
Hashim Uddin Ahmed,
Zeike Taylor,
Clare Allen,
Mark Emberton,
David Hawkes,
Dean Barratt
et al.
|
Full-length article
(In Press Corrected Proof)
|
14 December 2010 |
|
Reconstruction of a 3D surface from video that is robust to missing data and outliers: Application to minimally invasive surgery using stereo and mono endoscopes
DOI: 10.1016/j.media.2010.11.002
Graphical abstract: 3D structure is recovered from a moving endoscope in the presence of image noise, missing data and even outliers. It can provide a wide field-of-view and be used for 3D–3D registra...
|
Mingxing Hu,
Graeme Penney,
Michael Figl,
Philip Edwards,
Fernando Bello,
Roberto Casula,
Daniel Rueckert,
David Hawkes
et al.
|
Full-length article
(In Press Corrected Proof)
|
13 December 2010 |
|
Statistical modeling and recognition of surgical workflow
DOI: 10.1016/j.media.2010.10.001
Graphical abstract: . Research highlights: ► Statistical workflow modeling from demonstrated surgeries. ► DTW/HMM based methods for on-line and off-line surew representation of interventions in terms ...
|
Nicolas Padoy,
Tobias Blum,
Seyed-Ahmad Ahmadi,
Hubertus Feussner,
Marie-Odile Berger,
Nassir Navab
et al.
|
Full-length article
(In Press Corrected Proof)
|
09 December 2010 |
|
An integrated diagnosis and therapeutic system using intra-operative 5-aminolevulinic-acid-induced fluorescence guided robotic laser ablation for precision neurosurgery
DOI: 10.1016/j.media.2010.11.004
Graphical abstract: Research highlights: ► Development of an integrated diagnosis and therapeutic system for precision malignant gliomas resection. ► Concept proof of the integration of diagnostic an...
|
Hongen Liao,
Masafumi Noguchi,
Takashi Maruyama,
Yoshihiro Muragaki,
Etsuko Kobayashi,
Hiroshi Iseki,
Ichiro Sakuma
et al.
|
Full-length article
(In Press Corrected Proof)
|
29 November 2010 |
|
Computer assisted reconstruction of complex proximal humerus fractures for preoperative planning
DOI: 10.1016/j.media.2010.07.012
Graphical abstract: Research highlights: ► Semi-automatic fracture reconstruction in two consecutive registration steps. ► Efficient contralateral matching without relying on initial fragment positio...
|
Philipp Fürnstahl,
Gábor Székely,
Christian Gerber,
Jürg Hodler,
Jess Gerrit Snedeker,
Matthias Harders
et al.
|
Full-length article
(In Press Corrected Proof)
|
30 September 2010 |
|
Intra-operative 3D guidance and edema detection in prostate brachytherapy using a non-isocentric C-arm
DOI: 10.1016/j.media.2010.07.011
Graphical abstract: Research highlights: ► The proposed system is the first of a kind that makes intra-operative detection of edema possible. ► It achieves a significantly more homogeneous seed distr...
|
A. Jain,
A. Deguet,
I. Iordachita,
G. Chintalapani,
S. Vikal,
J. Blevins,
Y. Le,
E. Armour,
C. Burdette,
D. Song,
G. Fichtinger
et al.
|
Full-length article
(In Press Corrected Proof)
|
16 August 2010 |
|
Biomechanically constrained groupwise ultrasound to CT registration of the lumbar spine
DOI: 10.1016/j.media.2010.07.008
Abstract: We present a groupwise US to CT registration algorithm for guiding percutaneous spinal interventions. In addition, we introduce a comprehensive validation scheme that accounts for changes in...
|
Sean Gill,
Purang Abolmaesumi,
Gabor Fichtinger,
Jonathan Boisvert,
David Pichora,
Dan Borshneck,
Parvin Mousavi
et al.
|
Full-length article
(In Press Corrected Proof)
|
05 August 2010 |
|
CranialVault and its CRAVE tools: A clinical computer assistance system for deep brain stimulation (DBS) therapy
DOI: 10.1016/j.media.2010.07.009
Abstract: A number of methods have been developed to assist surgeons at various stages of deep brain stimulation (DBS) therapy. These include construction of anatomical atlases, functional databases, ...
|
Pierre-François D’Haese,
Srivatsan Pallavaram,
Rui Li,
Michael S. Remple,
Chris Kao,
Joseph S. Neimat,
Peter E. Konrad,
Benoit M. Dawant
et al.
|
Full-length article
(In Press Corrected Proof)
|
02 August 2010 |
|
Gaze-Contingent Motor Channelling, haptic constraints and associated cognitive demand for robotic MIS
DOI: 10.1016/j.media.2010.07.007
Graphical abstract: Research highlights: ► Human visual system coordinates are directly transformed into motor coordinates. ► Gaze-Contingent Motor Channelling improves motor targeting and task perfo...
|
George P. Mylonas,
Ka-Wai Kwok,
David R.C. James,
Daniel Leff,
Felipe Orihuela-Espina,
Ara Darzi,
Guang-Zhong Yang
et al.
|
Full-length article
(In Press Corrected Proof)
|
02 August 2010 |
|
Robotic Tissue Tracking for Beating Heart Mitral Valve Surgery
DOI: 10.1016/j.media.2010.06.007
Abstract: The rapid motion of the heart presents a significant challenge to the surgeon during intracardiac beating heart procedures. We present a 3D ultrasound-guided motion compensation system that ...
|
Shelten G. Yuen,
Nikolay V. Vasilyev,
Pedro J. del Nido,
Robert D. Howe
|
Full-length article
(In Press Accepted Manuscript)
|
08 July 2010 |
|
Fast virtual deployment of self-expandable stents: Method and in vitro evaluation for intracranial aneurysmal stenting
DOI: 10.1016/j.media.2010.04.009
Abstract: Introduction: Minimally invasive treatment approaches, like the implantation of percutaneous stents, are becoming more popular every day for the treatment of intracranial aneurysms. The outc...
|
Ignacio Larrabide,
Minsuok Kim,
Luca Augsburger,
Maria Cruz Villa-Uriol,
Daniel Rüfenacht,
Alejandro F. Frangi
et al.
|
Full-length article
(In Press Corrected Proof)
|
12 May 2010 |
|
A review of 3D/2D registration methods for image-guided interventions
DOI: 10.1016/j.media.2010.03.005
Abstract: Registration of pre- and intra-interventional data is one of the key technologies for image-guided radiation therapy, radiosurgery, minimally invasive surgery, endoscopy, and interventional ...
|
P. Markelj,
D. Tomaževič,
B. Likar,
F. Pernuš
|
Full-length article
(In Press Corrected Proof)
|
14 April 2010 |